+86 13720145047lunagangrui@gmail.com
    Follow Us
Products
Home >>Products >>High Voltage Tester
High Voltage Tester

Ultra-low frequency testing Equipment

  • Ultra-low frequency insulation withstand voltage test is actually an alternative to power frequency withstand voltage test. For large generators, cables and other test products for power frequency voltage test, it can replace large capacity resonant transformer.
Chat Now
Contact Us+86 13720145047

Details

Product Parameter

 

Input voltage

220V ±10% 50HZ ±1%/110KV ±10% 60HZ ±1%

Temperature

040℃

Relative humidity

≦90%

Output voltage

040KV 070KV

Output frequency and on load ability

0.1HZ: 1.1µ F

0.05HZ; 2.2µ F

0.02HZ: 5.5µ F

Voltmeter accuracy

≦3%

Amperemeter accuracy

≦5%

 

Model

Rated voltage

Load capacity

Power Fuse

Reference weight

 (30KV)

30kV/20mA

(Peak value)

0.1Hz,≤0.5µF~1.1µF

5A

Controller4kg

Booster25kg

0.05Hz,≤0.5µF~2.2µF

0.02Hz,≤0.5µF~5.5µF

 (50KV)

50kV/30mA

(Peak value)

0.1Hz,≤0.5µF~1.1µF

7A

Controller4kg

Booster50kg

0.05Hz,≤0.5µF~2.2µF

0.02Hz,≤0.5µF~5.5µF

(60KV)

60kV/30mA

(Peak value)

0.1Hz,≤0.5µF

9A

Controller4kg

Booster 1(30kV)25kg

Booster 2(30kV)25kg

0.05Hz,≤0.5µF~1µF

0.02Hz,≤0.5µF~2.5µF

 (80KV)

80kV/30mA

(Peak value)

0.1Hz,≤0.5µF

12A

Controller4kg

Booster 1(30kV)25kg

Booster 2(50kV)50kg

 

Product Feature And Application

 

1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself; the actuation time is less than 20ms.

3. Overcorrect protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.

4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

5. With the high and low voltage closed-loop negative feedback control circuit, the output is no capacitance rise effect.

6. Small volume, light weight, easy to carry

7. Has the regulator of frequency, can adjust the output frequency to 0.1,0.05 and 0.02 Hz

8. Can meet different requirement of the high voltage tester for cable and electric equipment with different model

 

Accessory

 

Number

name

Qty

1

0.1Hz/30kV control box

1

2

0.1Hz/30kV booster

1

3

0.1µF/30kV shunt capacitor

1

4

30kV High voltage output line

1

5

Shunt capacitive high voltage connection line

1

6

Special control cable

1

7

power line

1

8

ground lead

1set

9

70kVdischarging rod

1

10

10APower fuse

10

11

Printer paper

2

12

manual

1

13

certification

1

14

Inspection report

1

 

 


WhatsApp
Hotline

Service hotline

+86 13720145047